System Requirements

Technical Requirements for server and clients in custo diagnostic 5.x - dedicated to a clinical environment.

These requirements refer to custo diagnostic clinical 5.2.x and above.

Server

Hardware / Virtual Setup

Supported Operating Systems

(64bit Windows supported only)

Supported Database Systems and Database Servers

The H2 database which comes included with custo diagnostic 5.x Installer is not supported in a production environment of custo diagnostic clinical.

Client

Hardware / Virtual Setup

Supported Operating Systems

(32bit / 64bit Windows supported)

Windows Server can be used as a client or Windows Terminal Server - but not for an acquisition workplace.

Ports / Connections

Requirements for Bluetooth Connectivity

All Bluetooth devices of custo med are working at least with Bluetooth 2.0 EDR specification and are Class-2 devices - which means maximum of 10 meter distance from the device to the PC.  Do not use device and custo diagnostic application PC in different rooms. In circumstances where this is required (e.g. bedside ECG in infectious environments to avoid the contamination of the device trolley) please keep both in line of sigh.

System Architecture

custo diagnostic server is a Apache Tomcat based service. The process responds on ReST / http / https requests and access the database and the raw data directory. 

SQL Database for Patient and Examination Information

MariaDB for Patient and Examination Information

Raw Data Directory

Examination file sizes for storage usage calculation:

ProductFile size typical ca.File size max.
Holter ECG15MB60MB
ABPM128KB512KB
ABPM/Holter combi20MB25MB
Resting ECG200KB (10 Sek.)unlim.
Stress ECG20MB (20 Min.)unlim.
CPET20MB (20 Min.)unlim.
Spirometry50KB256KB
Cardiac Rehab Session6MB (45 Min.)unlim.
custo kybe15MB (24h)

Network connectivity

A recording of a holter ECG produces up to 10 MByte of data. 

For a WiFi based use of ECG recordings a stable, constant WiFi connection is necessary during recording and access.

Firewall setup (by clinic administrator): Server must only be accessible by administrators and Apache Tomcat User. All clients only access the custo diagnostic server by using http/https. 

(In environments of unstable / not constant WiFi connections custo supplies dedicated solutions. Please ask your dealer in this case.)


Remote access to customer systems for installation and maintanance


Operators Maintenance

Except when otherwise stipulated in written form, the clinic is the operator of the system and takes care for typical operator tasks.

Regarding the maintenance of hardware and software components, the following aspects should be monitored by the operator:

IT Security and Data Protection

custo diagnostic server is a windows service based on Apache Tomcat and a database server. 

General IT security tasks are part of the operators mainntainance and operating:

Anti-virus solutions

There is no general limitation for the usage of virus scanners.

In case of misbehavior or errors, custo med may ask the operator to limit/change the function of the virus scaner.


Subject to change without notice.